On the vCam-5 Control Module

1) Power on the vCam-5 control module
2) Press the F10 Menu key 2 times to enter the setup menu
3) Scroll down and select Video Out
4) Change the Video Out setting from “Camera” to “CVBS”
5) Check that the reel settings are correct in “Reel Settings”
6) Return to the main File Menu by pressing “ESC”
7) Turn off the vCam-5 control module

Connect all Interface Cables

Vivax-Metrotech Corporation

3251 Olcott Street

Santa Clara, CA 95054

+1 (800) 446-3392

8) Plug the male end of the RS232 cable into the RS232 port of the control module
9) Plug the USB end of the RS232 to USB cable into an available USB port on the PC
10) Attach a BNC to RCA adaptor to the Video In socket of the Sensoray unit
11) Plug in the RCA Video cable, 1 end into the Video Out socket of the control module and the other end into the Video In socket of the Sensoray unit
12) Plug in the RCA Audio cable, 1 end into the Audio Out socket of the control module and the other end into the Audio In socket of the Sensoray unit. (Use a RCA Male to 3.5mm adapter if needed)

13) Plug in the USB 2.0 A-Male to B-Male USB cable, 1 end into the Sensoray unit and the other into an available UBS port on the PC

14) Turn on the PC and vCam-5 control module

15) Launch the POSM software